Three ways to Order Products: TEC Store, or give uas a call at 612-827-1117 or visit one of our distributor partners.

TEC Price List
Click here if the price list page does not load automatically.

4) TECTITE 4.0

4) TECTITE 4.0 Image

Now compatible with the TEC DG-1000!

TECTITE 4.0  (WiFi) is The Energy Conservatory’s building airtightness test analysis programs for Windows-based computers. TECTITE makes it easier than ever to conduct fully automated blower door tests, and to analyze and store blower door test data.

The program’s built-in report generator and graphing capabilities makes it simple for you document and present the results of a blower door test to a homeowner or client. The programs is compatible with manual blower door testing (i.e. manual data entry), and fully automated tests using the DG-1000 or DG-700 Pressure and Flow Gauge.

Features of TECTITE 4.0 (WiFi)

  • Designed specifically for use with Minneapolis Blower Door systems.
  • Easy entry of all test settings and building information, and quick report generation.
  • Calculation and display of building airtightness test results including CFM50, air changes per hour, leakage areas, and building leakage curve.
  • Manual data entry mode allows you to easily enter manually collected test data.
  • Automated testing feature provides computerized control of Blower Door fan and automated flow and pressure measurements.
  • Reduces operator error, eliminates time spent zeroing gauges, and ensures that tests are conducted the same way every time.
  • “Pause Feature” allows the automated test to be temporarily paused and then re-started at the pause point.
  • Semi-auto test option allows computerized data collection while manually controlling the Blower Door fan.
  • Measure, record and report up to 6 additional building zone pressures during the automated Blower Door test (can use multiple DG-700 gauges).
  • “Deviations from Standard” reporting function. Data point deletion option. Real-time Air Change Per Hour at 50 Pa (ACH50) calculation during “Cruise Control.”
  • On-screen display is useful for quickly estimating building leakage rates before conducting a full test.
  • Program Help screens make program operation very user friendly.
  • WiFi connection for automated testing when the DG-1000 is used, or when the DG-700 Pressure and Flow Gauge is used with the TEC WiFi Link.
  • Built-in PDF file report generator.
  • Choice of 4 airtightness test standards: CGSB 149.10-M86 and the 3 RESNET test standards including One-Point, Multi-Point and Repeated Single-Point procedures.
  • Calculates estimated natural annual infiltration rate and the annual cost of air leakage.
  • Calculates need for mechanical ventilation based on estimated annual natural infiltration rates and ASHRAE 62.2-10 whole building ventilation guideline.
  • Estimated design infiltration rates can be used in Manual J load calculations.
  • Choice of report formats including a simple easy-to-read homeowner report, or a detailed technical report.
  • Compare feature generates test result comparison report for any two previously saved building files.

Videos

Category:
Software
Software Download Page:
tectite-4-0

4) TECTITE 4.0

4) TECTITE 4.0 Image

Now compatible with the TEC DG-1000!

TECTITE 4.0  (WiFi) is The Energy Conservatory’s building airtightness test analysis programs for Windows-based computers. TECTITE makes it easier than ever to conduct fully automated blower door tests, and to analyze and store blower door test data.

The program’s built-in report generator and graphing capabilities makes it simple for you document and present the results of a blower door test to a homeowner or client. The programs is compatible with manual blower door testing (i.e. manual data entry), and fully automated tests using the DG-1000 or DG-700 Pressure and Flow Gauge.

Features of TECTITE 4.0 (WiFi)

  • Designed specifically for use with Minneapolis Blower Door systems.
  • Easy entry of all test settings and building information, and quick report generation.
  • Calculation and display of building airtightness test results including CFM50, air changes per hour, leakage areas, and building leakage curve.
  • Manual data entry mode allows you to easily enter manually collected test data.
  • Automated testing feature provides computerized control of Blower Door fan and automated flow and pressure measurements.
  • Reduces operator error, eliminates time spent zeroing gauges, and ensures that tests are conducted the same way every time.
  • “Pause Feature” allows the automated test to be temporarily paused and then re-started at the pause point.
  • Semi-auto test option allows computerized data collection while manually controlling the Blower Door fan.
  • Measure, record and report up to 6 additional building zone pressures during the automated Blower Door test (can use multiple DG-700 gauges).
  • “Deviations from Standard” reporting function. Data point deletion option. Real-time Air Change Per Hour at 50 Pa (ACH50) calculation during “Cruise Control.”
  • On-screen display is useful for quickly estimating building leakage rates before conducting a full test.
  • Program Help screens make program operation very user friendly.
  • WiFi connection for automated testing when the DG-1000 is used, or when the DG-700 Pressure and Flow Gauge is used with the TEC WiFi Link.
  • Built-in PDF file report generator.
  • Choice of 4 airtightness test standards: CGSB 149.10-M86 and the 3 RESNET test standards including One-Point, Multi-Point and Repeated Single-Point procedures.
  • Calculates estimated natural annual infiltration rate and the annual cost of air leakage.
  • Calculates need for mechanical ventilation based on estimated annual natural infiltration rates and ASHRAE 62.2-10 whole building ventilation guideline.
  • Estimated design infiltration rates can be used in Manual J load calculations.
  • Choice of report formats including a simple easy-to-read homeowner report, or a detailed technical report.
  • Compare feature generates test result comparison report for any two previously saved building files.

Videos